{"id":315,"date":"2025-03-28T05:34:44","date_gmt":"2025-03-28T05:34:44","guid":{"rendered":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/chapter\/example-4-8-the-importance-of-boundary-conditions\/"},"modified":"2026-03-16T14:02:06","modified_gmt":"2026-03-16T14:02:06","slug":"example-4-8-the-importance-of-boundary-conditions","status":"publish","type":"chapter","link":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/chapter\/example-4-8-the-importance-of-boundary-conditions\/","title":{"raw":"Example 4.8","rendered":"Example 4.8"},"content":{"raw":"In this example we employ PLAXIS to validate the results of the simple, approximate method described in Section 4.5.4 for calculating immediate settlements of footings on linear elastic half-space. For that we will built two PLAXIS models, shown in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a>: A plane-strain one simulating a strip footing and an axisymmetric one simulating a circular footing.\n\nKeep in mind that the method described in Section 4.5.4 does not work for strip footings, as it predicts that infinite settlement will occur (see Table 4.3). To confirm that, we start by building a model in PLAXIS with initial thickness 10 m, and run 5 simulations in total while increasing the thickness of the mesh from <em>H <\/em>= 10 m to <em>H <\/em>= 50 m, <em>H <\/em>= 100 m, <em>H <\/em>= 150 m and finally <em>H <\/em>= 200 m. Indeed, it appears that the more we increase <em>H<\/em>, the larger the settlement (settlements increase linearly) and settlement tends to infinity for an infinitely thick mesh.\n\nHowever, results for a circular footing are rather puzzling. The analytical method yields an immediate settlement of 140 mm for the problem herein. Then we model the same problem in PLAXIS, starting with mesh thickness 10 m as shown in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a>, and again run multiple simulations while increasing <em>H <\/em>as above. Results of the first analysis for <em>H <\/em>= 10 m are relatively close to the analytical solution, as settlement from PLAXIS is about 170 mm. Keeping in mind that the solution is \u201capproximate\u201d, a 30 mm difference is acceptable, especially if we consider that the analytical method is applicable to rigid footings and in PLAXIS we are modelling an infinitely flexible footing by means of a pressure applied at the surface of the model. But as we keep increasing <em>H<\/em> again to 200 m, settlement yet again increases linearly instead of reaching an asymptote, as expected. The gradient is not as steep as in the strip footing case (notice the linear fit of\u00a0the numerical data), but at <em>H <\/em>= 200 m the PLAXIS settlement is already twice the analytical one, and we infer that it will reach 1.5 m if <em>H<\/em> was <em>H <\/em>= 2000 m. That\u2019s certainly not compatible with the analytical solution.\n\nIs there a fundamental error in the analytical method, or there is an error in our numerical models?\n\n&nbsp;\n\n[caption id=\"attachment_314\" align=\"aligncenter\" width=\"1024\"]<img class=\"wp-image-312 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-1024x1024.png\" alt=\"The figure on the top left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a radius 1 m. The figure on the top right shows a schematic of a plane strain model for a strip footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. The figure at the bottom shows results of these two analysis models, in terms of settlement increase with model thickness. Settlement of the strip footing increases rapidly to infinity as the mesh thickness increases. Settlement of the circular footing increases linearly as the mesh thickness increases, albeit at a slower rate. It is clear that the difference between the analytical solution and PLAXIS increases, and mesh thickness increases.\" width=\"1024\" height=\"1024\"> Figure 4.54. Evolution of footing settlement with increase in mesh thickness.[\/caption]\n<h2>Answer:<\/h2>\nIndeed, results presented in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a> are flawed, but the error lies in the numerical solution, and not in the analytical results. The question mentions that we increase the thickness of the mesh from 10 m to 200 m, but does not mention anything about changing proportionally the mesh width, as seen in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.55-HR.png\">Figure 4.55<\/a>.\n\nWhen standard fixities are used in a numerical model i.e., the horizontal displacement is fixed at the lateral boundaries, we set the particular boundary to be an axis of symmetry. Therefore a \u201cmirror\u201d loading acts at a horizontal distance e.g., 8 m from the strip footing in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.55-HR.png\">Figure 4.55<\/a> and contributes to settlement (see also additional Example 3.2).\n\nCorrect (i.e. not compromised by boundary effects) results are depicted in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.56-HR.png\">Figure 4.56<\/a>, and are obtained by increasing proportionally the mesh width to the mesh thickness. All other analysis parameters remain unchanged. Notice that indeed settlement of a strip footing increases indefinitely as the mesh thickness increases, as intuitively expected for a plane-strain pressure acting on the top of a half-space (when the out-of-plane displacement is fixed to satisfy symmetry).\n\nHowever, this is not the case for the circular footing, where settlement reaches an asymptote before the mesh thickness increases more than 40 m. In fact, the analytical solution is quite close to the numerical solution, and the above results verify its validity.\n\nThis rather crude example stresses out the importance of model boundary conditions in getting realistic results, and the need to carefully investigate the sensitivity of the solution to the boundary conditions (instead of relying on rules-of-thumb), to ensure that it is not compromised by errors introduced in the modelling stage. Analytical methods, such as the one described in Section 4.5.4 are invaluable for obtaining at least a first estimate of the expected solution.\n\n[caption id=\"attachment_314\" align=\"aligncenter\" width=\"1024\"]<img class=\"wp-image-313 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-1024x519.png\" alt=\"The figure on the left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a radius 1 m. A figure next to it shows the model in scale when H = 200 m, where it is clear that the lateral boundaries of the model are too close to the area of interest. The figure on the right shows a schematic of a plane strain model for a strip flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. A figure next to it shows the model in scale when H = 200 m, where it is clear (again) that the lateral boundaries of the model are too close to the area of interest. \" width=\"1024\" height=\"519\"> Figure 4.55. Simulated mesh dimensions for<em> H<\/em> = 200 m.[\/caption]\n\n&nbsp;\n\n[caption id=\"attachment_314\" align=\"aligncenter\" width=\"873\"]<img class=\"wp-image-314 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-873x1024.png\" alt=\"The figure on the top left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model is 200 m and the width of the model is now 200 m (increases proportionally to width). A pressure of 100 kPa is applied along a radius 1 m. The figure on the top right shows a schematic of a plane strain model for a strip footing. The thickness of the model is 200 m and the width of the model is again 200 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. The figure at the bottom shows results of these two analysis models, in terms of settlement increase with model thickness. Settlement of the strip footing increases again to infinity as the mesh thickness increases. Settlement of the circular footing remains practically constant as the mesh thickness increases. In this case PLAXIS predictions match well the results of the analytical solution.\" width=\"873\" height=\"1024\"> Figure 4.56. Evolution of footing settlement with increase in mesh thickness and mesh radius. Notice the vertical axis scale in comparison to Figure 4.55.[\/caption]","rendered":"<p>In this example we employ PLAXIS to validate the results of the simple, approximate method described in Section 4.5.4 for calculating immediate settlements of footings on linear elastic half-space. For that we will built two PLAXIS models, shown in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a>: A plane-strain one simulating a strip footing and an axisymmetric one simulating a circular footing.<\/p>\n<p>Keep in mind that the method described in Section 4.5.4 does not work for strip footings, as it predicts that infinite settlement will occur (see Table 4.3). To confirm that, we start by building a model in PLAXIS with initial thickness 10 m, and run 5 simulations in total while increasing the thickness of the mesh from <em>H <\/em>= 10 m to <em>H <\/em>= 50 m, <em>H <\/em>= 100 m, <em>H <\/em>= 150 m and finally <em>H <\/em>= 200 m. Indeed, it appears that the more we increase <em>H<\/em>, the larger the settlement (settlements increase linearly) and settlement tends to infinity for an infinitely thick mesh.<\/p>\n<p>However, results for a circular footing are rather puzzling. The analytical method yields an immediate settlement of 140 mm for the problem herein. Then we model the same problem in PLAXIS, starting with mesh thickness 10 m as shown in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a>, and again run multiple simulations while increasing <em>H <\/em>as above. Results of the first analysis for <em>H <\/em>= 10 m are relatively close to the analytical solution, as settlement from PLAXIS is about 170 mm. Keeping in mind that the solution is \u201capproximate\u201d, a 30 mm difference is acceptable, especially if we consider that the analytical method is applicable to rigid footings and in PLAXIS we are modelling an infinitely flexible footing by means of a pressure applied at the surface of the model. But as we keep increasing <em>H<\/em> again to 200 m, settlement yet again increases linearly instead of reaching an asymptote, as expected. The gradient is not as steep as in the strip footing case (notice the linear fit of\u00a0the numerical data), but at <em>H <\/em>= 200 m the PLAXIS settlement is already twice the analytical one, and we infer that it will reach 1.5 m if <em>H<\/em> was <em>H <\/em>= 2000 m. That\u2019s certainly not compatible with the analytical solution.<\/p>\n<p>Is there a fundamental error in the analytical method, or there is an error in our numerical models?<\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_314\" aria-describedby=\"caption-attachment-314\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-312 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-1024x1024.png\" alt=\"The figure on the top left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a radius 1 m. The figure on the top right shows a schematic of a plane strain model for a strip footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. The figure at the bottom shows results of these two analysis models, in terms of settlement increase with model thickness. Settlement of the strip footing increases rapidly to infinity as the mesh thickness increases. Settlement of the circular footing increases linearly as the mesh thickness increases, albeit at a slower rate. It is clear that the difference between the analytical solution and PLAXIS increases, and mesh thickness increases.\" width=\"1024\" height=\"1024\" srcset=\"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-1024x1024.png 1024w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-300x300.png 300w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-150x150.png 150w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-768x769.png 768w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-65x65.png 65w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-225x225.png 225w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR-350x350.png 350w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2025\/03\/4.54-HR.png 1272w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-314\" class=\"wp-caption-text\">Figure 4.54. Evolution of footing settlement with increase in mesh thickness.<\/figcaption><\/figure>\n<h2>Answer:<\/h2>\n<p>Indeed, results presented in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/03\/4.54-HR.png\">Figure 4.54<\/a> are flawed, but the error lies in the numerical solution, and not in the analytical results. The question mentions that we increase the thickness of the mesh from 10 m to 200 m, but does not mention anything about changing proportionally the mesh width, as seen in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.55-HR.png\">Figure 4.55<\/a>.<\/p>\n<p>When standard fixities are used in a numerical model i.e., the horizontal displacement is fixed at the lateral boundaries, we set the particular boundary to be an axis of symmetry. Therefore a \u201cmirror\u201d loading acts at a horizontal distance e.g., 8 m from the strip footing in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.55-HR.png\">Figure 4.55<\/a> and contributes to settlement (see also additional Example 3.2).<\/p>\n<p>Correct (i.e. not compromised by boundary effects) results are depicted in <a href=\"https:\/\/oercollective.caul.edu.au\/app\/uploads\/sites\/143\/2025\/02\/4.56-HR.png\">Figure 4.56<\/a>, and are obtained by increasing proportionally the mesh width to the mesh thickness. All other analysis parameters remain unchanged. Notice that indeed settlement of a strip footing increases indefinitely as the mesh thickness increases, as intuitively expected for a plane-strain pressure acting on the top of a half-space (when the out-of-plane displacement is fixed to satisfy symmetry).<\/p>\n<p>However, this is not the case for the circular footing, where settlement reaches an asymptote before the mesh thickness increases more than 40 m. In fact, the analytical solution is quite close to the numerical solution, and the above results verify its validity.<\/p>\n<p>This rather crude example stresses out the importance of model boundary conditions in getting realistic results, and the need to carefully investigate the sensitivity of the solution to the boundary conditions (instead of relying on rules-of-thumb), to ensure that it is not compromised by errors introduced in the modelling stage. Analytical methods, such as the one described in Section 4.5.4 are invaluable for obtaining at least a first estimate of the expected solution.<\/p>\n<figure id=\"attachment_314\" aria-describedby=\"caption-attachment-314\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-313 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-1024x519.png\" alt=\"The figure on the left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a radius 1 m. A figure next to it shows the model in scale when H = 200 m, where it is clear that the lateral boundaries of the model are too close to the area of interest. The figure on the right shows a schematic of a plane strain model for a strip flexible footing. The thickness of the model ranges from 10 m to 200 m and the width of the model is 10 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. A figure next to it shows the model in scale when H = 200 m, where it is clear (again) that the lateral boundaries of the model are too close to the area of interest.\" width=\"1024\" height=\"519\" srcset=\"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-1024x519.png 1024w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-300x152.png 300w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-768x389.png 768w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-1536x778.png 1536w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-2048x1037.png 2048w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-65x33.png 65w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-225x114.png 225w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.55-HR-350x177.png 350w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-314\" class=\"wp-caption-text\">Figure 4.55. Simulated mesh dimensions for<em> H<\/em> = 200 m.<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_314\" aria-describedby=\"caption-attachment-314\" style=\"width: 873px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-314 size-large\" src=\"https:\/\/libraryresources.nse.org.ng\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-873x1024.png\" alt=\"The figure on the top left shows a schematic of an axisymmetric model for a circular flexible footing. The thickness of the model is 200 m and the width of the model is now 200 m (increases proportionally to width). A pressure of 100 kPa is applied along a radius 1 m. The figure on the top right shows a schematic of a plane strain model for a strip footing. The thickness of the model is 200 m and the width of the model is again 200 m. A pressure of 100 kPa is applied along a width 2 m, at the middle of the model. The figure at the bottom shows results of these two analysis models, in terms of settlement increase with model thickness. Settlement of the strip footing increases again to infinity as the mesh thickness increases. Settlement of the circular footing remains practically constant as the mesh thickness increases. In this case PLAXIS predictions match well the results of the analytical solution.\" width=\"873\" height=\"1024\" srcset=\"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-873x1024.png 873w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-256x300.png 256w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-768x901.png 768w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-65x76.png 65w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-225x264.png 225w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR-350x411.png 350w, https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-content\/uploads\/sites\/9\/2026\/03\/4.56-HR.png 980w\" sizes=\"(max-width: 873px) 100vw, 873px\" \/><figcaption id=\"caption-attachment-314\" class=\"wp-caption-text\">Figure 4.56. Evolution of footing settlement with increase in mesh thickness and mesh radius. Notice the vertical axis scale in comparison to Figure 4.55.<\/figcaption><\/figure>\n","protected":false},"author":1,"menu_order":17,"template":"","meta":{"pb_show_title":"","pb_short_title":"Example 4.8","pb_subtitle":"The importance of boundary conditions","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-315","chapter","type-chapter","status-publish","hentry"],"part":215,"_links":{"self":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapters\/315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapters\/315\/revisions"}],"predecessor-version":[{"id":316,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapters\/315\/revisions\/316"}],"part":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/parts\/215"}],"metadata":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapters\/315\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/wp\/v2\/media?parent=315"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/pressbooks\/v2\/chapter-type?post=315"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/wp\/v2\/contributor?post=315"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/libraryresources.nse.org.ng\/fundamentalsoffoundationengineering\/wp-json\/wp\/v2\/license?post=315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}